Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathCONFIG.TXT
115 lines (94 loc) · 4.89 KB
/
CONFIG.TXT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
# Configuration file for TAMDL COPY FILE ON SD CARD
#
# Revision History
# 2019-02-10,rage Added SCAN_DURATION, described U and I threshold values.
# 2018-10-10,rage Added variables for Power Cycle Interval and On Duration.
# 2018-03-15,rage Initial version
#########################################################################
# #
# IMPORTANT NOTE: All time values must be specified in STANDARD time, #
# i.e. MEZ! If DCF77 time is MESZ (daylight saving #
# time), they will automatically converted to MESZ. #
# #
#########################################################################
# Configuration Variables in config.txt:
# RFID_TYPE [SR, LR]
# RFID reader device type: SR is Short Range reader, LR is Long Range reader.
# If no type is specified (i.e. the variable is #-commented), the associated
# logic will not be activated.
# RFID_POWER [UA1, UA2, BATT]
# RFID reader power source, must be set to UA1 or UA2.
# If no value is specified (i.e. the variable is #-commented), the associated
# logic will not be activated.
# RFID_ABSENT_DETECT_TIMEOUT [s]
# An RFID reader regularly re-sends the ID, as long as the transponder can be
# received. This is used to retrigger a "still present" timer. The value
# specifies the time in seconds, after which the transponder is treated as
# "absent" when its ID could not be received again.
# A value of 0 disables the absent logic. This is useful for "fly thru"
# designs, e.g. with the Smart Nest Box.
# UA1_ON_TIME_1~5, UA1_OFF_TIME_1~5, UA2_ON_TIME_1~5, UA2_OFF_TIME_1~5,
# BATT_ON_TIME_1~5, BATT_OFF_TIME_1~5 [hour:min] MEZ
# These variables determine the on and off times of the UA1, respective UA2
# power output. If an RFID reader is assigned to an output, the UART will be
# activated additionally.
# UA1_INTERVAL, UA1_ON_DURATION, UA2_INTERVAL, UA2_ON_DURATION, BATT_INTERVAL,
# and BATT_ON_DURATION in [s]
# These optional variables allow you to define a Power Cycle Interval within
# the on times of the respective power output. XXX_INTERVAL specifies the
# interval in seconds, XXX_ON_DURATION the power ON duration in seconds
# within this interval.
# The OFF duration is calculated XXX_INTERVAL minus XXX_ON_DURATION.
# There exists only one set of values per output. These are applicable for
# all five on/off-times.
# UA1_MEASURE_FOLLOW_UP_TIME, UA2_MEASURE_FOLLOW_UP_TIME, and
# BATT_MEASURE_FOLLOW_UP_TIME [s]
# Duration in [s], the measurement of the respective power output is still
# performed. Additionally, BATT_INP voltage and current is measured via
# the battery controller. For the BATT output, only BATT_INP is measured.
# SCAN_DURATION [ms]
# When the ADC has been activated for voltage and current measurements,
# this variable specifies how long it lasts to measure one channel. There
# are four ADC channels in use: Voltage and current for UA1 and also for UA2
# (Battery data is read from its controller). Within this duration, 2048
# single measurements are done per channel, which performs the calculation
# of an average value. Default value is 1000ms.
# UA1_MEASURE_U_MIN_DIFF, UA1_MEASURE_I_MIN_DIFF, UA2_MEASURE_U_MIN_DIFF [mV],
# and UA2_MEASURE_I_MIN_DIFF [mA]
# Threshold values for voltage [mV] and current [mA]. No update is done,
# if values change within this range. Defaults are 100mV and 10mA.
# UA1_CALIBRATE_mV, UA2_CALIBRATE_mV [mV]
# Calibration reference voltage for UA1 and UA2, specified in [mV].
# UA1_CALIBRATE_mA, UA2_CALIBRATE_mA [mA]
# Calibration reference current for UA1 and UA2, specified in [mA].
# Calibration values for UA1 and UA2 measuring
UA1_CALIBRATE_mV = 9005
UA1_CALIBRATE_mA = 926
UA2_CALIBRATE_mV = 4888
UA2_CALIBRATE_mA = 696
# RFID configuration
RFID_TYPE = LR
RFID_POWER = UA1
RFID_ABSENT_DETECT_TIMEOUT = 5
# Follow-up times after measurement [s]
UA1_MEASURE_FOLLOW_UP_TIME = 60
UA2_MEASURE_FOLLOW_UP_TIME = 60
BATT_MEASURE_FOLLOW_UP_TIME = 30
# Operating times for UA1 output [hour:min] MEZ
UA1_ON_TIME_1 = 05:00
UA1_OFF_TIME_1 = 15:00
# Power Cycle Interval for UA1 output [s]
UA1_INTERVAL = 600 # 10min Interval
UA1_ON_DURATION = 300 # 5min On Duration
# Operating times for UA2 output [hour:min] MEZ
#UA2_ON_TIME_1 = 07:00
#UA2_OFF_TIME_1 = 13:00
# Power Cycle Interval for UA2 output [s]
#UA2_INTERVAL = 400
#UA2_ON_DURATION = 300
# Operating times for BATT output [hour:min] MEZ
#BATT_ON_TIME_1 = 07:00
#BATT_OFF_TIME_1 = 12:00
# Power Cycle Interval for BATT output [s]
#BATT_INTERVAL = 60
#BATT_ON_DURATION = 20