Wrong UTC time #412
Comments
Currently I can see the exact same problem on an on older version namely |
After reading this comment, I concuded, that the clock on my RC30 thermostat also seems to be unaware of the daylight saving time, and I guess that needs to be manually corrected? |
its the same code since v3.0 and I'm sure after 2am you would have seen the same issue. Can you try a different NTP server like one from https://www.pool.ntp.org/zone/europe |
@proddy Thanks, cz.pool.ntp.org works fine for me. |
Regarding the manual time setting the dst is not calculated and give wrong setting. I'm not sure if it is better/possible to extract this from timezone-setting or add a checkbox to set dst. |
@MichaelDvP I believe that having a reliable default NTP time would also be welcome since the time syncs with thermostats and, as a consequence, predefined heating schedule shifts. And such shift/incorrect time is hard to recognize and can not be fixed by correcting time on the physical termostat (it syncs back). |
fix #412, daylightsaving with manual time setting
I've fixed the manual setting with dst. |
Bug description
After installing the 3.4.0b9 version (updating from 3.3.1 today), ems-esp shows wrong UTC time. It is shifted by 1 hour, regardless of manual input or NTP. I am in the Prague/Europe time zone. I suspect this to be related to the change of winter-to-summer time.
Steps to reproduce
Change time manually or turn on NTP.
Expected behavior
Correct time to be shown. Currently, the time is shifted by 1 hour.
Screenshots

Correct time is shown in the statusbar. Correct UTC is that time minus 2 hours.
Device information
{
"System": {
"version": "3.4.0b9",
"uptime": "000+06:14:35.078",
"uptime (seconds)": 22475,
"freemem": 152,
"reset reason": "Software reset CPU / Software reset CPU",
"temperature sensors": 0
},
"Network": {
"connection": "WiFi",
"hostname": "ems-esp",
"SSID": "hodnekrabic",
"BSSID": "D8:07:B6:C8:96:B6",
"RSSI": -53,
"MAC": "7C:87:CE:49:A3:14",
"IPv4 address": "192.168.68.113/255.255.255.0",
"IPv4 gateway": "192.168.68.1",
"IPv4 nameserver": "0.0.0.0"
},
"Status": {
"bus status": "connected",
"bus protocol": "HT3",
"bus telegrams received (rx)": 25378,
"bus reads (tx)": 6422,
"bus writes (tx)": 19,
"bus incomplete telegrams": 0,
"bus reads failed": 0,
"bus writes failed": 0,
"bus rx line quality": 100,
"bus tx line quality": 100,
"MQTT status": "connected",
"MQTT publishes": 10066,
"MQTT publish fails": 0,
"temperature sensors": 0,
"temperature sensor reads": 0,
"temperature sensor fails": 0,
"analog sensors": 0,
"API calls": 2,
"API fails": 0
},
"Devices": [
{
"type": "Boiler",
"name": "Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3",
"device id": "0x08",
"product id": 95,
"version": "18.14",
"entities": 64,
"handlers received": "0x10 0x11 0x15 0x1C 0x18 0x19 0x1A 0x35 0x34",
"handlers fetched": "0x14 0x16 0x33",
"handlers pending": "0xC2 0x26 0x2A"
},
{
"type": "Thermostat",
"name": "RC300/RC310/Moduline 3000/1010H/CW400/Sense II",
"device id": "0x10",
"product id": 158,
"version": "18.05",
"entities": 64,
"handlers received": "0x06 0xA2 0x02BB 0x02BC 0x02BD 0x02BE 0x02BF 0x02C0 0x031D 0x0267",
"handlers fetched": "0x02A5 0x02B9 0x02AF 0x029B 0x02A6 0x02BA 0x02B0 0x029C 0x02F5 0x031B 0x023A 0x0240",
"handlers pending": "0xA3 0x12 0x0471 0x0472 0x02A7 0x02B1 0x029D 0x0473 0x02A8 0x02B2 0x029E 0x0474 0x02A9 0x02B3 0x029F 0x0475 0x02AA 0x02B4 0x02A0 0x0476 0x02AB 0x02B5 0x02A1 0x0477 0x02AC 0x02B6 0x02A2 0x0478 0x031E"
},
{
"type": "Mixer",
"name": "MM100",
"device id": "0x21",
"product id": 160,
"version": "24.05",
"entities": 4,
"handlers received": "0x02D8"
},
{
"type": "Controller",
"name": "HT3",
"device id": "0x09",
"product id": 95,
"version": "18.14",
"entities": 0
}
]
}
Additional context