Victron VEDirect EspHome component supporting HEX and TEXT protocol

License

Notifications You must be signed in to change notification settings

krahabb/esphome-victron-vedirect

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

50 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

esphome-victron-vedirect

This EspHome external component contains a complete implementation to support Victron VEDirect serial interface. It has parsers for both the HEX and the TEXT protocol data carried over the communication channel and allows to also issue commands in order to configure the Victron device.

Beside this 'quick and dirty' README you can have a look at the complete docs here

In order to use an ESP (both legacy ESP8266 and/or any ESP32 variant) to connect to a VEDirect hardware interface it uses one of the UART buses available in the ESP platform. The code itself is optimized (or can be) to use the minimum amount of resources but, depending on the number of entities configured you might be better off using one of the more capable ESP32 versions so to have more RAM and CPU power for the task.

The details for hardware interfacing can be found online and this repo doesn't provide many clues but you have to basically adapt and connect the VEDirect RX/TX data lines to the ESP uart bus. Now this might be as simple as directly wiring those RX/TX lines to the UART pins of the ESP if the VEDirect device uses 3.3 V operation or, if the interface carries 5V signals, you might be better off using an optocoupler (H11L1 might be needed because of the data transfer rate used in the signaling) or any form of signal level adaptation.

Before using this component I strongly suggest to understand how VEDirect works by deeply checking these (and any other possibly available) docs:

The first document being the overall technical description and explaining what is achievable with the TEXT protocol while the others are a more detailed description of the HEX protocol features available among the different classes of devices.

Sadly enough, beside those few documents, Victron doesn't expose a very detailed 'implementation manual' for every device/family, especially the new ones (like the RS families of devices for instance) so, many times you'll have to infer or guess how to interface with these by looking at their most close counterparts for which documentation is available. As an example, I'm using this code and the knowledge from those docs to succesfully (at least partially) interface a Multi RS inverter which contains both MPPTs and INVERTERs features (plus many which are very specific and for which there's no official doc available). At any rate, for basic sensor readings and configuration those documents are enough since, even among different devices and classes, the configuration registers are pretty almost the same.

How to use

In order to include the component in your EspHome project use the instructions. Something in the lines:

external_components:
  source: github://krahabb/esphome-victron-vedirect

There are some sample configurations with a basic explanation of the features for different scenarios:

These samples mostly use the 'auto create' feature in order to automatically create an entity for any register data appearing on the communication channel. This might help to start over but could soon become cumbersome since HEX broadcasted registers might be a lot and the component will create HA entities for any of these.

These other samples show instead usage of static entities definition for different 'flavors'. See manual configuration for better insights.

We'll see then how to better configure the device for only the needed entities.

Manual configuration

Victron devices expose a lot of registers each one carrying either measured data (battery voltage for instance) or a configuration parameter (or some static info like device model, hw & sw revision, and so on). In general, TEXT frames only carry a subset of these (both measures and some info/configuration), while HEX frames can address and carry any register. Since there are so many registers and most of them are unknown, this component allows you to specify all of the details needed to decode/map any register data to a specific entity (this is an advanced feature and you really need to know how those registers work). This will be covered later.

For simple use cases instead you can use some 'well known' registers definitions which are already embedded in the component (this is related to the 'flavor' configuration). We'll go with some examples for really basic and widely used registers in order to understand this.

Example 1: Configure some sensors for battery voltage, battery current, pv power. Here things might be tricky since the component nomenclature tries to use the same conventional names used by Victron docs so let's start to say that (in general) battery voltage in Victron appliances is carried in register VE_REG_DC_CHANNEL1_VOLTAGE (and the same reasoning is behind the other entities). Having said that, in order to setup these sensors you have to configure it like this (for other configuration settings check the samples):

m3_vedirect:
  - id: vedirect_0
    uart_id: uart_0
    name: "Victron"
    flavor: [ALL]
    textframe:
      auto_create_entities: false
    hexframe:
      auto_create_entities: false
      ping_timeout: 2min

sensor:
  - platform: m3_vedirect
    vedirect_id: vedirect_0    
    vedirect_entities:
      - register: DC_CHANNEL1_VOLTAGE
        name: 'Battery voltage'
      - register: DC_CHANNEL1_CURRENT
        name: 'Battery current'
      - register: PANEL_POWER
        name: 'PV power'

Using the register configuration will automatically set all of the needed info in order to correctly decode the register carrying the battery voltage (DC_CHANNEL1_VOLTAGE) and setup the sensor entity with proper unit, digits, scale, device class, state class. Now, keep in mind the DC_CHANNEL1_VOLTAGE-DC_CHANNEL1_CURRENT-PANEL_POWER registers are defined as NUMERIC in 'component terms' and that allows them to be configured as (numeric) sensors (this is useful when inspecting the list of available pre-defined registers published later in order to know which kind of entity supports it)

Let's see another useful Example 2: configure a text_sensor for DEVICE_STATE

text_sensor:
  - platform: m3_vedirect
    vedirect_id: vedirect_0    
    vedirect_entities:
      - register: DEVICE_STATE
        name: 'Device state (enum)'

Register DEVICE_STATE (hex address 0x0201) is encoded as an ENUM and this component carries (hardcoded in english) the different labels associated with those enum values (according to Victron official nomenclature) so that the text sensor will show you these labels instead of numeric values. This is true for any register defined as ENUM so that the text sensor will always try to map the numeric value to a meaningful label. If you want to see the underlying numeric value it is possible though: just use a sensor definition instead of a text_sensor:

sensor:
  - platform: m3_vedirect
    vedirect_id: vedirect_0
    vedirect_entities:
      - register: DEVICE_STATE
        name: 'Device state (raw)'

More: you can map the same register (DEVICE_STATE) to more than one entity so that you can see it in different representations (both as a sensor and a text_sensor). The component will dispatch the incoming raw data to all of the entities representing it.

Register definitions

This table exposes the list of actually pre-defined registers to be used with the 'shortcut' configuration register. It is extracted from the source file definitions in ve_reg_register.h which is always the 'source of truth' for the component.

register hex address class r/w flavor
BLE_MODE 0x0090 BITMASK READ_WRITE ANY
PRODUCT_ID 0x0100 VOID CONSTANT ANY
APP_VER 0x0102 VOID CONSTANT ANY
SERIAL_NUMBER 0x010A STRING CONSTANT ANY
MODEL_NAME 0x010B STRING CONSTANT ANY
CAPABILITIES 0x0140 BITMASK CONSTANT ANY
CAPABILITIES_BLE 0x0150 BITMASK CONSTANT ANY
DEVICE_MODE 0x0200 ENUM READ_WRITE ANY
DEVICE_STATE 0x0201 ENUM READ_ONLY ANY
DEVICE_OFF_REASON 0x0205 BITMASK READ_ONLY ANY
DEVICE_OFF_REASON_2 0x0207 BITMASK READ_ONLY ANY
INVERTER_DEVICE_STATE 0x0209 ENUM READ_ONLY INV
CHARGER_DEVICE_STATE 0x020A ENUM READ_ONLY CHG
AC_OUT_VOLTAGE_SETPOINT 0x0230 NUMERIC READ_WRITE INV
MPPT_TRACKERS 0x0244 NUMERIC CONSTANT MPPT_RS
U_OUTPUT_YIELD 0x0310 NUMERIC READ_ONLY MULTI_RS
U_USER_YIELD 0x0311 NUMERIC READ_ONLY MULTI_RS
WARNING_REASON 0x031C BITMASK READ_ONLY ANY
ALARM_REASON 0x031E BITMASK READ_ONLY ANY
ALARM_LOW_VOLTAGE_SET 0x0320 NUMERIC READ_WRITE INV
ALARM_LOW_VOLTAGE_CLEAR 0x0321 NUMERIC READ_WRITE INV
RELAY_CONTROL 0x034E BOOLEAN READ_WRITE ANY
RELAY_MODE 0x034F ENUM READ_WRITE ANY
TTG 0x0FFE NUMERIC READ_ONLY BMV
SOC 0x0FFF NUMERIC READ_ONLY BMV
SOLAR_ACTIVITY 0x2030 BOOLEAN READ_ONLY MPPT
TIME_OF_DAY 0x2031 NUMERIC READ_ONLY MPPT
AC_OUT_VOLTAGE 0x2200 NUMERIC READ_ONLY INV
AC_OUT_CURRENT 0x2201 NUMERIC READ_ONLY INV
AC_OUT_APPARENT_POWER 0x2205 NUMERIC READ_ONLY INV
SHUTDOWN_LOW_VOLTAGE_SET 0x2210 NUMERIC READ_WRITE INV
VOLTAGE_RANGE_MIN 0x2211 NUMERIC CONSTANT INV
VOLTAGE_RANGE_MAX 0x2212 NUMERIC CONSTANT INV
U_AC_OUT_VOLTAGE 0x2213 NUMERIC READ_ONLY MULTI_RS
U_AC_OUT_CURRENT 0x2214 NUMERIC READ_ONLY MULTI_RS
U_AC_OUT_REAL_POWER 0x2215 NUMERIC READ_ONLY MULTI_RS
U_AC_OUT_APPARENT_POWER 0x2216 NUMERIC READ_ONLY MULTI_RS
TWO_WIRE_BMS_INPUT_STATE 0xD01F BITMASK READ_ONLY MPPT_RS
REMOTE_INPUT_MODE_CONFIG 0xD0C0 ENUM READ_WRITE MPPT_RS
U_AC_OUT_CURRENT_MA 0xD3A1 NUMERIC READ_ONLY MULTI_RS
MPPT_TRACKER_MODE_1 0xECC3 ENUM READ_ONLY MPPT_RS
PANEL_VOLTAGE_1 0xECCB NUMERIC READ_ONLY MPPT_RS
PANEL_POWER_1 0xECCC NUMERIC READ_ONLY MPPT_RS
PANEL_CURRENT_1 0xECCD NUMERIC READ_ONLY MPPT_RS
MPPT_TRACKER_MODE_2 0xECD3 ENUM READ_ONLY MPPT_RS
PANEL_VOLTAGE_2 0xECDB NUMERIC READ_ONLY MPPT_RS
PANEL_POWER_2 0xECDC NUMERIC READ_ONLY MPPT_RS
PANEL_CURRENT_2 0xECDD NUMERIC READ_ONLY MPPT_RS
MPPT_TRACKER_MODE_3 0xECE3 ENUM READ_ONLY MPPT_RS
PANEL_VOLTAGE_3 0xECEB NUMERIC READ_ONLY MPPT_RS
PANEL_POWER_3 0xECEC NUMERIC READ_ONLY MPPT_RS
PANEL_CURRENT_3 0xECED NUMERIC READ_ONLY MPPT_RS
MPPT_TRACKER_MODE_4 0xECF3 ENUM READ_ONLY MPPT_RS
PANEL_VOLTAGE_4 0xECFB NUMERIC READ_ONLY MPPT_RS
PANEL_POWER_4 0xECFC NUMERIC READ_ONLY MPPT_RS
PANEL_CURRENT_4 0xECFD NUMERIC READ_ONLY MPPT_RS
BATTERY_RIPPLE_VOLTAGE 0xED8B NUMERIC READ_ONLY MPPT_RS
DC_CHANNEL1_VOLTAGE 0xED8D NUMERIC READ_ONLY ANY
DC_CHANNEL1_POWER 0xED8E NUMERIC READ_ONLY BMV
DC_CHANNEL1_CURRENT 0xED8F NUMERIC READ_ONLY ANY
LOAD_OUTPUT_STATE 0xEDA8 BOOLEAN READ_ONLY MPPT
LOAD_CURRENT 0xEDAD NUMERIC READ_ONLY MPPT
MPPT_TRACKER_MODE 0xEDB3 ENUM READ_ONLY MPPT
PANEL_MAXIMUM_VOLTAGE 0xEDB8 NUMERIC CONSTANT MPPT
PANEL_VOLTAGE 0xEDBB NUMERIC READ_ONLY MPPT
PANEL_POWER 0xEDBC NUMERIC READ_ONLY MPPT
PANEL_CURRENT 0xEDBD NUMERIC READ_ONLY MPPT
PANEL_MAXIMUM_CURRENT 0xEDBF NUMERIC CONSTANT MPPT_RS
VOLTAGE_COMPENSATION 0xEDCA NUMERIC READ_WRITE MPPT
MAXIMUM_POWER_YESTERDAY 0xEDD0 NUMERIC READ_ONLY MPPT
YIELD_YESTERDAY 0xEDD1 NUMERIC READ_ONLY MPPT
MAXIMUM_POWER_TODAY 0xEDD2 NUMERIC READ_ONLY MPPT
YIELD_TODAY 0xEDD3 NUMERIC READ_ONLY MPPT
CHARGER_VOLTAGE 0xEDD5 NUMERIC READ_ONLY CHG
CHARGER_CURRENT 0xEDD7 NUMERIC READ_ONLY CHG
CHR_ERROR_CODE 0xEDDA ENUM READ_ONLY CHG
CHR_INTERNAL_TEMPERATURE 0xEDDB NUMERIC READ_ONLY CHG
USER_YIELD 0xEDDC NUMERIC READ_ONLY MPPT
SYSTEM_YIELD 0xEDDD NUMERIC READ_ONLY MPPT
BAT_LOW_TEMP_LEVEL 0xEDE0 NUMERIC READ_WRITE MPPT
REBULK_VOLTAGE_OFFSET 0xEDE2 NUMERIC READ_WRITE MPPT
EQUALISATION_DURATION 0xEDE3 NUMERIC READ_WRITE MPPT
EQUALISATION_CURRENT_LEVEL 0xEDE4 NUMERIC READ_WRITE MPPT
AUTO_EQUALISE_STOP_ON_VOLTAGE 0xEDE5 BOOLEAN READ_WRITE MPPT
LOW_TEMP_CHARGE_CURRENT 0xEDE6 NUMERIC READ_WRITE MPPT
BMS_PRESENT 0xEDE8 BOOLEAN READ_WRITE MPPT
BAT_VOLTAGE_SETTING 0xEDEA ENUM READ_WRITE MPPT
BAT_TEMPERATURE 0xEDEC NUMERIC READ_ONLY ANY
BAT_VOLTAGE 0xEDEF NUMERIC READ_ONLY MPPT
BAT_MAX_CURRENT 0xEDF0 NUMERIC READ_WRITE MPPT
BAT_TYPE 0xEDF1 ENUM READ_WRITE MPPT
BAT_TEMPERATURE_COMPENSATION 0xEDF2 NUMERIC READ_WRITE MPPT
BAT_EQUALISATION_VOLTAGE 0xEDF4 NUMERIC READ_WRITE MPPT
BAT_FLOAT_VOLTAGE 0xEDF6 NUMERIC READ_WRITE MPPT
BAT_ABSORPTION_VOLTAGE 0xEDF7 NUMERIC READ_WRITE MPPT
BAT_ABSORPTION_LIMIT 0xEDFB NUMERIC READ_WRITE MPPT
BAT_BULK_LIMIT 0xEDFC NUMERIC READ_WRITE MPPT
AUTOMATIC_EQUALISATION_MODE 0xEDFD NUMERIC READ_WRITE MPPT
ADAPTIVE_MODE 0xEDFE BOOLEAN READ_WRITE MPPT
DC_MONITOR_MODE 0xEEB8 NUMERIC READ_ONLY BMV71
ALARM_BUZZER 0xEEFC BOOLEAN READ_WRITE BMV

The 'flavor' property is used to conditionally include the corresponding definition(s) in the code. This works as an optimization for code size so that it is possible to decide which of the registers must be defined. It is controlled by the configuration key in the main platform configuration:

m3_vedirect:
  - id: vedirect_0
    uart_id: uart_0
    name: "Victron"
    flavor: [ALL] # include all flavors i.e. all of the register definitions

If you want to use a particular register definition you have to ensure the corresponding flavor is set.

The 'class' and 'r/w' properties are very important and state which kind of data the register is carrying and if it's read only or writable. Different 'classes' and 'r/w' can be supported by different EspHome entity types according to the following table:

class r/w primary entity
BITMASK READ_ONLY binary_sensor(1)
BITMASK READ_WRITE switch(1)
BOOLEAN READ_ONLY binary_sensor
BOOLEAN READ_WRITE switch
ENUM READ_ONLY text_sensor
ENUM READ_WRITE select
NUMERIC READ_ONLY sensor
NUMERIC READ_WRITE number
STRING READ_ONLY text_sensor

(1) in order to use a binary_sensor or switch for BITMASK registers you'd also have to set the configuration property mask which, as the name implies, is used to extract/mask the intended bit from the register value (representing a bitmask for the matter).

binary_sensor:
  - platform: m3_vedirect
    vedirect_id: vedirect_0
    vedirect_entities:
      - register: DEVICE_OFF_REASON_2
        name: 'No input power'
        mask: 1 # Bit 0 of DEVICE_OFF_REASON bitmask

Beside these 'primary entity' mappings you can always use a sensor entity to represent the raw value as a numeric value even if the register is not marked as NUMERIC (though some sign conversion issues might happen since the conversion would be done as an unsigned type whenever the class is not NUMERIC). Moreover, the text_sensor entity too can represent any class data type, generally falling back to report the hex register value 'as is' (if no better conversion is provided by the register definition).

More help and wiki will come.

Good interfacing!